Hi Experts,
I am trying to use RRMS_MESSAGE_HANDLING for a customer exit variable and I am really not sure how to use it. My question is:
How to define I_CLASS? The data element says this is Application Area. Can someone tell me wht this is? and how I can define it?
Any additional information about how to use this function for i_step = 3 would be very helpful. I need to popup a warning message for the user if they enter a wrong value for a user exit variable.
Thanks
Deepa

Answers

hi Deepa,
check the doc 'how to verify variable input' ...
https://websmp106.sap-ag.de/~sapdownload/011000358700002765042003E/HowToVerifyVariableInput.pdf
hope this helps.
CALL FUNCTION 'RRMS_MESSAGE_HANDLING'
EXPORTING
I_CLASS = 'RSBBS'
I_TYPE = 'I'
I_NUMBER = '000'
I_MSGV1 = 'your message'.
RAISE no_replacement.

Read other 3 answers

Tags:

Related Articles

  • Variable entry warning with RRMS_MESSAGE_HANDLINGOctober 11

    Hi, If I post a message in the Variable Exit (I_STEP = 3) with the function module RRMS_MESSAGE_HANDLING, the user cannot execute the variable until a valid entry exists. I would like to only raise an information that appears only once and the user c

  • About Func. module RRMS_MESSAGE_HANDLINGNovember 30

    I am trying to use RRMS_MESSAGE_HANDLING for a customer exit variable and I am really not sure how to use it. My question is: How to define I_CLASS? The data element says this is Application Area. Can someone tell me wht this is? and how I can define

  • RRMS_MESSAGE_HANDLINGNovember 30

    Hi Experts, I am trying to use RRMS_MESSAGE_HANDLING for a customer exit variable and I am really not sure how to use it. My question is: How to define I_CLASS? The data element says this is Application Area. Can someone tell me wht this is? and how

  • Impossible to generate information message with 'RRMS_MESSAGE_HANDLING'November 30

    Hello I would like to generate Informative message once the variable screen is available for user entry. The message from FM (see code beloe) is generated once the query result is up. IF step = 2. CALL FUNCTION 'RRMS_MESSAGE_HANDLING' EXPORTING I_CLA

  • RRMS_MESSAGE_HANDLING - Solution to implement for BW ProjectNovember 30

    Hi SDN Community, I have followed the SAPNet document: How to verify ... variable input But i cannot get it to work on the web. Does anyone have any working code they able to send me please. here is the design of our query: - i have the following use

  • How to create a verification pop-up message for queries executed on WebOctober 11

    I have implemented the function RRMS_MESSAGE_HANDLING in my customer exit variable code for step 2  in the customer include ZXRSRU01.  I am able to get warning and error messages to appear in Bex Excel queries, but not queries executed on the Web.  I

  • Pop up message on the variable screen in portal when report is runOctober 11

    Hello I have a requirement to pop up a message stating " Date should not be entered before 2010 "on the variable screen of the report if date is entered before 2010 by the user when the report is run. Please can someone tell me how to implement

  • Error message in Bex Variable screenOctober 11

    Hello All, In my BW I have a new variable of type interval for the selection criterion calendar year/month . I want to check high value of the interval if it is lesser than or equal to current calendar year/month (that is 201405)  then report can be

  • How to show a message in a query BI7?October 11

    Hi everybody, In BI7, I need to show an error message that the selection screen of a query to after checking a variable. I tried the following in the code of customer exit for variables (step 3): 1. Put "MESSAGE E899(bd) WITH text-008" but after

  • Message at the variable screenOctober 11

    Hello, I would like that message pops up at the variable screen during the execution of the report. How can I implement this functionality? ThanksHi, Use the following Code, don't write in between Case and EndCase, after ENDCASE you write code for I_